D-Flow has developed evaluation platforms for hot and cold air, natural gas, fuel vapour, propane and other applications at capacities from DN 10 up to DN 70.

The D-Flow UFO ASIC handles two pairs of transducers for dual-path solutions. Multi-path solutions can be achieved by using more than one ASIC on the same electronics board.

Typical performance of gas flow meters based on D-Flow technology is displayed below. The performance has been validated in air at temperatures between 15°C and 55°C. D-Flow gas flow platforms comply with the uncertainty statements of the natural gas specification ENV 14236. All uncertainty statements are made with a 95 % confidence level.

Zero flow stability: ± 2 mm/s.
Maximum flow velocity: ~30 m/s.
Repeatability: ± 0.3%.
Total accuracy: < ± 1% of measured value in a range of 1:150.
Total accuracy: < ± 2% of measured value in a range of 1:300.