The Sing Around technology for analysis
A speed of sound measurement works exactly like a flow measurement except that the speed of sound is calculated instead of the flow rate. For example, in a flow meter set-up the two equations expressing the two sound propagation times t1 and t2 can be used. By combining the two equations the fluid velocity vm can be eliminated and the speed of sound c can be solved as:
c = L/2 (1/ t1 + 1/ t2)

If the fluid velocity is zero (t = t1 = t2) the expression can be reduced to:
c = L/ t

The total uncertainty of the speed of sound measurement is dominated by the calibration of the distance between the transducers. The repeatability of speed of sound measurements using D-Flow technology is better than ± 10 mm/s.